Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 10 de 10
Filter
Add more filters










Publication year range
1.
Radiother Oncol ; 190: 109953, 2024 Jan.
Article in English | MEDLINE | ID: mdl-37839557

ABSTRACT

BACKGROUND AND PURPOSE: The FLASH effect has been validated in different preclinical experiments with electrons (eFLASH) and protons (pFLASH) operating at an average dose rate above 40 Gy/s. However, no systematic intercomparison of the FLASH effect produced by eFLASHvs. pFLASH has yet been performed and constitutes the aim of the present study. MATERIALS AND METHODS: The electron eRT6/Oriatron/CHUV/5.5 MeV and proton Gantry1/PSI/170 MeV were used to deliver conventional (0.1 Gy/s eCONV and pCONV) and FLASH (≥110 Gy/s eFLASH and pFLASH) dose rates. Protons were delivered in transmission. Dosimetric and biologic intercomparisons were performed using previously validated dosimetric approaches and experimental murine models. RESULTS: The difference between the average absorbed dose measured at Gantry 1 with PSI reference dosimeters and with CHUV/IRA dosimeters was -1.9 % (0.1 Gy/s) and + 2.5 % (110 Gy/s). The neurocognitive capacity of eFLASH and pFLASH irradiated mice was indistinguishable from the control, while both eCONV and pCONV irradiated cohorts showed cognitive decrements. Complete tumor response was obtained after an ablative dose of 20 Gy delivered with the two beams at CONV and FLASH dose rates. Tumor rejection upon rechallenge indicates that anti-tumor immunity was activated independently of the beam-type and the dose-rate. CONCLUSION: Despite major differences in the temporal microstructure of proton and electron beams, this study shows that dosimetric standards can be established. Normal brain protection and tumor control were produced by the two beams. More specifically, normal brain protection was achieved when a single dose of 10 Gy was delivered in 90 ms or less, suggesting that the most important physical parameter driving the FLASH sparing effect might be the mean dose rate. In addition, a systemic anti-tumor immunological memory response was observed in mice exposed to high ablative dose of electron and proton delivered at CONV and FLASH dose rate.


Subject(s)
Biological Products , Neoplasms , Proton Therapy , Humans , Animals , Mice , Protons , Electrons , Radiotherapy Dosage , Radiometry
2.
Radiat Res ; 200(4): 357-365, 2023 10 01.
Article in English | MEDLINE | ID: mdl-37702413

ABSTRACT

Significant past work has identified unexpected risks of central nervous system (CNS) exposure to the space radiation environment, where long-lasting functional decrements have been associated with multiple ion species delivered at low doses and dose rates. As shielding is the only established intervention capable of limiting exposure to the dangerous radiation fields in space, the recent discovery that pions, emanating from regions of enhanced shielding, can contribute significantly to the total absorbed dose on a deep space mission poses additional concerns. As a prerequisite to biological studies evaluating pion dose equivalents for various CNS exposure scenarios of mice, a careful dosimetric validation study is required. Within our ultimate goal of evaluating the functional consequences of defined pion exposures to CNS functionality, we report in this article the detailed dosimetry of the PiMI pion beam line at the Paul Scherrer Institute, which was developed in support of radiobiological experiments. Beam profiles and contamination of the beam by protons, electrons, positrons and muons were characterized prior to the mice irradiations. The dose to the back and top of the mice was measured using thermoluminescent dosimeters (TLD) and optically simulated luminescence (OSL) to cross-validate the dosimetry results. Geant4 Monte Carlo simulations of radiation exposure of a mouse phantom in water by charged pions were also performed to quantify the difference between the absorbed dose from the OSL and TLD and the absorbed dose to water, using a simple model of the mouse brain. The absorbed dose measured by the OSL dosimeters and TLDs agreed within 5-10%. A 30% difference between the measured absorbed dose and the dose calculated by Geant4 in the dosimeters was obtained, probably due to the approximated Monte Carlo configuration compared to the experiment. A difference of 15-20% between the calculated absorbed dose to water at a 5 mm depth and in the passive dosimeters was obtained, suggesting the need for a correction factor of the measured dose to obtain the absorbed dose in the mouse brain. Finally, based on the comparison of the experimental data and the Monte Carlo calculations, we consider the dose measurement to be accurate to within 15-20%.


Subject(s)
Mesons , Animals , Mice , Radiometry/methods , Protons , Central Nervous System , Monte Carlo Method , Thermoluminescent Dosimetry/methods , Water , Phantoms, Imaging
3.
bioRxiv ; 2023 Apr 21.
Article in English | MEDLINE | ID: mdl-37131769

ABSTRACT

Background and purpose: The FLASH effect has been validated in different preclinical experiments with electrons (eFLASH) and protons (pFLASH) operating at a mean dose rate above 40 Gy/s. However, no systematic intercomparison of the FLASH effect produced by e vs. pFLASH has yet been performed and constitutes the aim of the present study. Materials and methods: The electron eRT6/Oriatron/CHUV/5.5 MeV and proton Gantry1/PSI/170 MeV were used to deliver conventional (0.1 Gy/s eCONV and pCONV) and FLASH (≥100 Gy/s eFLASH and pFLASH) irradiation. Protons were delivered in transmission. Dosimetric and biologic intercomparisons were performed with previously validated models. Results: Doses measured at Gantry1 were in agreement (± 2.5%) with reference dosimeters calibrated at CHUV/IRA. The neurocognitive capacity of e and pFLASH irradiated mice was indistinguishable from the control while both e and pCONV irradiated cohorts showed cognitive decrements. Complete tumor response was obtained with the two beams and was similar between e and pFLASH vs. e and pCONV. Tumor rejection was similar indicating that T-cell memory response is beam-type and dose-rate independent. Conclusion: Despite major differences in the temporal microstructure, this study shows that dosimetric standards can be established. The sparing of brain function and tumor control produced by the two beams were similar, suggesting that the most important physical parameter driving the FLASH effect is the overall time of exposure which should be in the range of hundreds of milliseconds for WBI in mice. In addition, we observed that immunological memory response is similar between electron and proton beams and is independent off the dose rate.

4.
Radiat Prot Dosimetry ; 174(2): 167-174, 2017 Apr 25.
Article in English | MEDLINE | ID: mdl-27311733

ABSTRACT

In situ gamma spectrometry is a valuable tool to assess the radionuclides released in the environment and the associated dose. This requires prior establishment of coefficients allowing the conversion of the specific activity into ambient equivalent dose. The aim of this work is to calculate updated conversion factors for monoenergetic photons and for a series of radionuclides of interest. The calculation was performed using the Monte Carlo (MC) method, the GEANT4 MC code, various activity distribution models and up-to-date nuclear decay data. A new set of conversion factors is established in the energy range extending from  <100 keV to 8.5 MeV. The coefficients calculated in this work were compared to the data published in the literature.


Subject(s)
Photons , Radioisotopes , Spectrometry, Gamma , Computer Simulation , Monte Carlo Method , Radiometry
5.
Phys Lett B ; 761: 281-286, 2016 10.
Article in English | MEDLINE | ID: mdl-28057978

ABSTRACT

The hypothesis that proximity to the Sun causes variation of decay constants at permille level has been tested and disproved. Repeated activity measurements of mono-radionuclide sources were performed over periods from 200 days up to four decades at 14 laboratories across the globe. Residuals from the exponential nuclear decay curves were inspected for annual oscillations. Systematic deviations from a purely exponential decay curve differ from one data set to another and are attributable to instabilities in the instrumentation and measurement conditions. The most stable activity measurements of alpha, beta-minus, electron capture, and beta-plus decaying sources set an upper limit of 0.0006% to 0.008% to the amplitude of annual oscillations in the decay rate. Oscillations in phase with Earth's orbital distance to the Sun could not be observed within a 10-6 to 10-5 range of precision. There are also no apparent modulations over periods of weeks or months. Consequently, there is no indication of a natural impediment against sub-permille accuracy in half-life determinations, renormalisation of activity to a distant reference date, application of nuclear dating for archaeology, geo- and cosmochronology, nor in establishing the SI unit becquerel and seeking international equivalence of activity standards.

6.
Radiat Prot Dosimetry ; 167(1-3): 302-5, 2015 Nov.
Article in English | MEDLINE | ID: mdl-25948829

ABSTRACT

Swiss national requirements for measuring radon gas exposures demand a lower detection limit of 50 kBq h m(-3), representing the Swiss concentration average of 70 Bq m(-3) over a 1-month period. A solid-state nuclear track detector (SSNTD) system (Politrack, Mi.am s.r.l., Italy) has been acquired to fulfil these requirements. This work was aimed at the calibration of the Politrack system with traceability to international standards and the development of a procedure to check the stability of the system. A total of 275 SSNTDs was exposed to 11 different radon exposures in the radon chamber of the Secondary Calibration Laboratory at the Paul Scherrer Institute, Switzerland. The exposures ranged from 50 to 15000 kBq h m(-3). For each exposure of 20 detectors, 5 SSNTDs were used to monitor possible background exposures during transport and storage. The response curve and the calibration factor of the whole system were determined using a Monte Carlo fitting procedure. A device to produce CR39 samples with a reference number of tracks using a (241)Am source was developed for checking the long-term stability of the Politrack system. The characteristic limits for the detection of a possible system drift were determined following ISO Standard 11929.


Subject(s)
Air Pollutants, Radioactive/analysis , Air Pollution, Indoor/analysis , Radiometry/instrumentation , Radiometry/standards , Radon/analysis , Semiconductors/standards , Air Pollutants, Radioactive/standards , Calibration/standards , Internationality , Monte Carlo Method , Radiometry/methods , Radon/standards , Reproducibility of Results , Sensitivity and Specificity , Switzerland
7.
Appl Radiat Isot ; 70(9): 1990-6, 2012 Sep.
Article in English | MEDLINE | ID: mdl-22421399

ABSTRACT

The work presented here is a new and precise measurement of the half-life of (166m)Ho by determining the activity concentration, using an ionisation chamber calibrated for this nuclide, and measuring the number of (166m)Ho atoms using multi-collector inductively coupled plasma mass spectrometry (MC-ICP-MS). Since the isotope (166)Er interferes with the mass spectrometric measurement, Er has to be eliminated from the (166m)Ho radioactive solution. The elimination was achieved using ion-exchange chromatography with the cation exchange resin Dowex AG 50W-X8 and 2-Hydroxybutanoic acid as the mobile phase. After a first transit through the chromatographic column, the purified (166m)Ho eluate was spiked with natural Er to get a resulting Er isotopic composition close to that of natural Er at better than 99.5%, and then it underwent two further separations to eliminate the Er. The activity concentration of this Er-free radioactive (166m)Ho solution was measured in our reference ionisation chamber calibrated for this nuclide by means of the 4πß(PC)-γ and 4πß(PS)-4πγ coincidence techniques and integral counting with a well-type NaI(Tl) detector and Monte Carlo efficiencies. An aliquot of this standardized solution was sent to the Paul Scherrer Institute (PSI) for mass concentration determination using an isotope dilution MC-ICP-MS approach. The mass concentration of (166m)Ho in this solution was determined with 0.25% relative standard uncertainty. This value was corroborated by two other independent measurements. The new half-life of (166m)Ho, 1132.6(39) years (k=1), is compatible with the value determined in 1965, but is 5.6% shorter and about 43 times more precise.


Subject(s)
Holmium/chemistry , Mass Spectrometry/instrumentation , Radioisotopes/chemistry , Radiometry/instrumentation , Radiometry/standards , Chromatography, Ion Exchange , Equipment Design , Equipment Failure Analysis , Half-Life , Holmium/analysis , Internationality , Radiation Dosage , Radioisotopes/analysis , Reference Standards , Reference Values
8.
Radiat Prot Dosimetry ; 144(1-4): 505-9, 2011 Mar.
Article in English | MEDLINE | ID: mdl-21149292

ABSTRACT

In Switzerland, individuals exposed to the risk of activity intake are required to perform regular monitoring. Monitoring consists in a screening measurement and is meant to be performed using commonly available laboratory instruments. More particularly, iodine intake is measured using a surface contamination monitor. The goal of the present paper is to report the calibration method developed for thyroid screening instruments. It consists of measuring the instrument response to a known activity located in the thyroid gland of a standard neck phantom. One issue of this procedure remains that the iodine radioisotopes have a short half-life. Therefore, the adequacy and limitations to simulate the short-lived radionuclides with so-called mock radionuclides of longer half-life were also evaluated. In light of the results, it has been decided to use only the appropriate iodine sources to perform the calibration.


Subject(s)
Equipment Contamination , Iodine Radioisotopes/analysis , Occupational Exposure/prevention & control , Thyroid Gland/diagnostic imaging , Calibration , Equipment Design , Humans , Models, Statistical , Phantoms, Imaging , Polyethylene/chemistry , Radiation Monitoring/instrumentation , Radiation Monitoring/methods , Radiation Protection/instrumentation , Radiation Protection/methods , Radionuclide Imaging , Reproducibility of Results , Sodium Iodide/chemistry , Switzerland , Thyroid Gland/radiation effects
9.
Radiat Prot Dosimetry ; 144(1-4): 326-9, 2011 Mar.
Article in English | MEDLINE | ID: mdl-20959333

ABSTRACT

Monte Carlo simulations were carried out to study the response of a thyroid monitor for measuring intake activities of (125)I and (131)I. The aim of the study was 3-fold: to cross-validate the Monte Carlo simulation programs, to study the response of the detector using different phantoms and to study the effects of anatomical variations. Simulations were performed using the Swiss reference phantom and several voxelised phantoms. Determining the position of the thyroid is crucial for an accurate determination of radiological risks. The detector response using the Swiss reference phantom was in fairly good agreement with the response obtained using adult voxelised phantoms for (131)I, but should be revised for a better calibration for (125)I and for any measurements taken on paediatric patients.


Subject(s)
Iodine Radioisotopes/analysis , Radiation Monitoring/instrumentation , Radiometry/instrumentation , Thyroid Gland/diagnostic imaging , Body Size , Computer Simulation , Female , Humans , Male , Monte Carlo Method , Phantoms, Imaging , Radiation Monitoring/methods , Radiometry/methods , Radionuclide Imaging , Reproducibility of Results , Software , Switzerland , Thyroid Gland/pathology
10.
Appl Radiat Isot ; 68(7-8): 1207-10, 2010.
Article in English | MEDLINE | ID: mdl-20153206

ABSTRACT

An international exercise, registered as EUROMET project no. 907, was launched to measure both the activity of a solution of (124)Sb and the photon emission intensities of its decay. The same solution was sent by LNE-LNHB to eight participating laboratories. In order to identify possible biases, the participants were asked to use all possible activity measurement methods available in their laboratory and then to determine their reference value for comparison. Thus, measurement results from 4pibeta-gamma coincidence/anti-coincidence counting, CIEMAT/NIST liquid-scintillation counting, 4pigamma counting with well-type ionization chambers and well-type crystal detectors were given. The results are compared and show a maximum discrepancy of about 1.6%: possible explanations are proposed.


Subject(s)
Antimony/analysis , Antimony/standards , International Cooperation , Photons , Reference Values , Reproducibility of Results , Scintillation Counting , Solutions , Weights and Measures
SELECTION OF CITATIONS
SEARCH DETAIL
...